Altium designer 17 run script free download

Altium designer 17 run script free download

Looking for:

Altium designer 17 run script free download

Click here to Download

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The advantage of this approach is that running the script as a process avoids the need to directly open the script or have it loaded as a Global Project. The second and more significant advantage of using the process method to run a script is that it can be implemented as an accessible Altium Designer command.

This is done by customizing Altium Designer’s menu system, where a script can be assigned to a command for a nominated server — that is, a sub-application such as the file system or a design document editor.

The dialog also can be accessed by right-clicking on a menu bar or toolbar then choosing Customize from the drop-down menu or by double-clicking in a blank area away from any commands of a menu bar or toolbar. To create a new command, click the dialog’s New button to open the Edit Command dialog where the server process and script path details can be included — ensure that the [Scripts] category is not selected when creating a command from a script.

These settings are saved with the command and apply to all instances where it is inserted in menus, toolbars and pop-ups — as described in the Assigning Menu Commands section below.

TIP: The required parameters can be copied from the actual script entry under the [Scripts] category in the Customize PCB Editor dialog if the script is currently loaded.

To temporarily load the script, browse to and open it via the File » Run Script command. Once copied, ensure that the Categories entry is no longer set to [Scripts] before creating the command with the New button. With the details complete and the edit dialog dismissed , the HelloWorld script becomes available as a Custom command under [Custom] for the PCB Editor. An external application such as the Microsoft Notepad can be launched from Altium Designer through software control.

In this case the command process and parameters entries would be:. The software process in this case, ScriptingSystem:RunScriptText , is literally running a sequence of script statements, rather than opening and running a specific script file as outlined above.

The alternative approach is to create a script with a few equivalent lines of code, then create a conventional ScriptingSystem:RunScript command entry. Note that for both approaches to implementing the external Notepad command it is sufficient to just enter ‘notepad.

Windows applications such as Calculator and Notepad have their paths already specified by the operating system. To launch an application from Altium Designer that does not have an inherent Windows path, the application’s full path and filename need to be specified in single quotes, to cater for any white space in the path. So to launch a second copy of Altium Designer for example, the RunApplication process and parameters would be:.

EXE’ — where xx represents Altium Designer version folder name. With a script implemented as a custom server command via Altium Designer’s Customizing function View » Toolbars » Customize as detailed above, it can be assigned to the server GUI by a simple drag and drop process.

To assign a custom command to the PCB editor’s main menu or Toolbar menu for example, open the Customizing PCB Editor dialog, locate the custom command and drag it to the desired menu location. With the customizing dialog closed, the new menu command can be accessed at any time in the PCB editor. A custom command can be dragged to the required menu location. When assigned to a menu, the custom script command will appear under that menu’s category in the customizing dialog.

To remove a command from a menu, open the custom dialog then drag the menu command icon back into the dialog. Removing a command assigned to the Toolbar. A custom command can be assigned to a menu, at any menu depth, using the same drag and drop process described above. The pre-packaged process launchers bundle together the process that runs when the command is selected, plus any parameters, bitmaps icons , captions the name of an item that displays on a resource , descriptions and associated shortcut keys.

A command can be linked or duplicated when it is added to a bar. A linked command will be updated if the original process launcher is modified. A duplicated command, however, will remain as a copy of the original process launcher and not be updated. Duplicated commands can be modified to create a new command by changing its process launcher properties. To add a command to a bar:. It is often easier to create a new command by duplicating an existing command that is similar then modify its parameters.

To duplicate a command:. Deleting a customized command stored in the Custom category will delete all instances of the custom command from all resources. From the Toolbars tab of the Customizing Editor dialog, you can select which main menu and toolbars to display, create a new or duplicate toolbar, as well as rename, delete or restore toolbars.

To create a new toolbar:. If you want to create a new toolbar based on an existing toolbar, it is easier to duplicate the original toolbar and edit the commands. Toolbars will only appear on the screen if they are active. Select which toolbars are active displayed on the Toolbars tab on the Customizing Editor dialog.

When the Is Active box is enabled checked , the associated toolbar is active and will be displayed. With the Customizing Editor dialog open, select the command in a menu or toolbar you want to duplicate or link.

You can nominate which main menu bar is active displayed by selecting a menu from the Bar to use as Main Menu drop-down on the Toolbars tab in the Customizing Editor dialog. Use the following steps to restore the original default menus and toolbars and delete all customizations:. You can add a line separator above the item in a menu or before an icon in a toolbar.

With the Customizing Editor dialog open, right-click on a menu or toolbar item then select Begin Group. These files are:. On the Commands tab of the Customizing Editor dialog, [System Level] includes the commands to ‘toggle floating panel visibility’ and to toggle floating panel focus’.

A custom scheme can also be defined for a folder, simply by typing it within the field, ensuring that the variable portion is enclosed in curly braces e. When creating the target Script Item in which to store your script project, ensure that its Content Type is set to Script in the Create New Item dialog. If you are creating the Item in a Scripts type folder, this Item type will be available from the right-click context menu when creating the Item.

Creating a Script Item within a Scripts folder – the correct Content Type is available on the context menu. When defining the Script Item, to which the source script project is uploaded, be sure to specify the type of lifecycle management to be used for the Item, and the naming scheme employed for its revisions, respectively. Control over which Item types can use a particular lifecycle definition or revision naming scheme, can be defined and enabled at a global level from within the Content Types dialog , when defining each schema.

So far, we’ve discussed the support for a Script Item in the server, in terms of related folder and item types. Uploading a script project into the revision of such an item can be performed by right-clicking on the required Script Item in the Explorer panel , and choosing the Upload command from the context menu.

Specifying the script project file to be uploaded to the target Script Item. With the desired file selected, proceed with the upload by clicking the Open button. The project file, along with all files in the same folder, are uploaded to the revision, and will be available on the Details aspect view tab for that revision, in the Explorer panel. The uploaded project, along with all files in the same folder, are listed on the Details aspect view tab for the revision of the Script Item.

A script project can also be uploaded into a new Script Item by dragging the selected script project file and related source files from a source folder in your Windows Explorer, and dropping into the required folder in the Explorer panel.

The Create New Item dialog will appear, with the dragged files listed in the Sources region. The Name of the item will be the file names, including extension entries will be separated by a semi-colon.

Change these as required. Uploading a script project and related files to the initial revision of a newly-created Script Item, using the drag and drop method. Related page: Controlling Access to Server Content. Once a script project has been uploaded to a managed content server, and its lifecycle state set to a level that the organization views as ready for use at the design level, that script can be reused in future board-level design projects.

When you are signed in to your managed content server, you are free to manually reuse the revisions of any Script Items that have been shared with you. Choose to run a script from a managed content server source, rather than a local source, by using the From server command in the Select Item to Run dialog.

Altium Designer allows any number of script projects to be installed on a permanent basis, so their functionality becomes available at all times, for all Altium Designer sessions. This feature is available from the Scripting System – Global Projects page of Altium Designer’s Preferences dialog click on the control at the top-right of the main design window. To install a script project from your managed content server, click the button and choose the Install from server command from the associated menu.

Select the desired managed script Item from the subsequent Choose Item dialog essentially an incarnation of the Explorer panel , and click OK to install the script project. Installed scripts are always available in Altium Designer, and are configured on the Scripting System – Global Projects page of the Preferences dialog. The installed script project will be available to Altium Designer whenever a user is signed in to the managed content server with suitable credentials.

Note that the installed script project is listed by its location or ‘path’ within the server’s folder structure, and the ID of the Script Item containing the script project data.

A managed script installed from a managed content server is listed by its server path and Item ID. In Altium Designer, a script either locally or server-sourced can be applied to a menu item with a number of simple steps. This relies on the permanent availability of that script, which must be installed through the Scripting Preferences as detailed previously.

 
 

 

Altium Designer PCB Library – FREE – Footprints – Symbols – 3D Models

 

Any number of footprint model links may be specified, and this will be a welcome feature for those wishing to create components that reference 3 footprints, satisfying the IPC requirements for different density levels L least or minimum copper , M most, or maximum copper , and N nominal, or median copper.

As this allows any file to be added to an OutJob, native Altium Designer files can also be included in specific release categories such as Fabrication or Assembly data. Altium Designer works with Managed Projects by providing simplified, direct access to the Vault-based project data, and also offers a host of advanced new project management features. Within the Vault, a Managed Project is inherently associated with its released production data, with both the design source and manufacturing output available from a single unified location.

The GUI to this process – the Library Migrator view – presents an intuitive flow that takes initial selected libraries, and migrates them to a target Altium Vault. And while the migration process can be configured – giving you enhanced control over how that migration is performed – at its most simplistic, you can simply accept the default settings and set the migration in motion within a matter of clicks.

The Altium Vault 3. In Altium Designer And when placing components from such an Integrated Library, the actual links are back to the Component Items in the vault. This gives you the ability to effectively use your company’s vault components in an offline fashion, while ensuring the design still maintains a true connection to those components in the source vault. The Item Manager provides a fast and effective way to convert a PCB project to one that uses fully managed library components from a centralized Altium Vault.

This ability – essentially validating that vault components in a design are all up-to-date and using the latest revisions of their parent Component Items – can be checked as part of project compilation. At the heart of this checking is the Component revision is Out of Date violation type, part of the category: Violations Associated with Components. Configure the reporting mode for this check on the Error Reporting tab of the Project Options dialog.

New in Altium Designer. Using Altium Documentation. Now reading version For the latest, read: New in Altium Designer for version Read more Many of the new features and enhancements summarized here require the latest release of the Altium Vault – Altium Vault 3. Printer-friendly version. Found an issue with this document? Contact Us Contact our corporate or local offices directly. We’re sorry to hear the article wasn’t helpful to you. Could you take a moment to tell us why?

Connect to Support Center for product questions. As this allows any file to be added to an OutJob, native Altium Designer files can also be included in specific release categories such as Fabrication or Assembly data. Altium Designer works with Managed Projects by providing simplified, direct access to the Vault-based project data, and also offers a host of advanced new project management features.

Within the Vault, a Managed Project is inherently associated with its released production data, with both the design source and manufacturing output available from a single unified location. The GUI to this process – the Library Migrator view – presents an intuitive flow that takes initial selected libraries, and migrates them to a target Altium Vault. And while the migration process can be configured – giving you enhanced control over how that migration is performed – at its most simplistic, you can simply accept the default settings and set the migration in motion within a matter of clicks.

The Altium Vault 3. In Altium Designer And when placing components from such an Integrated Library, the actual links are back to the Component Items in the vault. This gives you the ability to effectively use your company’s vault components in an offline fashion, while ensuring the design still maintains a true connection to those components in the source vault.

The Item Manager provides a fast and effective way to convert a PCB project to one that uses fully managed library components from a centralized Altium Vault. This ability – essentially validating that vault components in a design are all up-to-date and using the latest revisions of their parent Component Items – can be checked as part of project compilation.

At the heart of this checking is the Component revision is Out of Date violation type, part of the category: Violations Associated with Components.

Configure the reporting mode for this check on the Error Reporting tab of the Project Options dialog. New in Altium Designer. Using Altium Documentation. Now reading version For the latest, read: New in Altium Designer for version Read more Many of the new features and enhancements summarized here require the latest release of the Altium Vault – Altium Vault 3. Printer-friendly version. Found an issue with this document?

Contact Us Contact our corporate or local offices directly. We’re sorry to hear the article wasn’t helpful to you. Could you take a moment to tell us why? Connect to Support Center for product questions. I do not want to leave feedback. Use a preset Item Naming Scheme or create a custom scheme. Using the nominated naming scheme, the software will automatically assign the next available unique ID based on that scheme, while avoiding a naming clash with any existing Items in the Vault.

Also, the Naming Scheme employed for the parent folder can be changed at any time — the modified scheme will then be applied to any subsequent newly-created Items within that folder. The following Create Item dialog offers all properties settings for the new Item, including Comment and Description fields that will help with quick identification of Script Items when searching the Vault.

Add a meaningful Comment and Description to a new Script Item so that Vault searches are more effective — note the Search tab at the bottom of the Vaults panel. When the Create Item dialog is dismissed OK , the new Script Item is created in the target Scripts folder, where it exists in an initial Planned Revision state until populated with the released Script project. How Revisions of an Item are named, and how those revisions progress through their Lifecycle States, are determined by the Item’s Revision Naming Scheme and Lifecycle Definition, respectively.

Again, these should be set to sensible defaults, but can be changed when or after the Item is created — but before Script data has been uploaded released to that Item Revision. Use the drop down menus to select a different Scheme or Definition. Revision Naming Schemes and Lifecycle Definitions can be edited, and if desired, only applied to specific types of content. Further to this, control over which Item types can use a particular lifecycle definition or revision naming scheme can be globally defined and enabled from the Content Types dialog.

This is accessed from the Content Types link in the Edit Revision Naming Scheme or Edit Lifecycle Definition dialogs above , and when opened, will apply to the currently selected tab in the editing dialog the 1-Level Revision Scheme tab, for example, as shown above. A created Script Item will be in a Planned state until a Script Project is uploaded into the initial Revision, where it will normally progress to a read-only In Production state.

Removing a command assigned to the Toolbar. A custom command can be assigned to a menu, at any menu depth, using the same drag and drop process described above. When the server is in customizing mode the menus remain responsive to the mouse pointer, and will expand and contract accordingly.

To place a command into the PCB editor’s Reports menu for example, drag the command into the menu and down the list where it can be dropped in a suitable position. With the customizing dialog closed, the new menu command — here, Notepad — can be accessed from within the Reports menu. Active menus during customization allow a custom command to be dragged into a drop-down menu. A command can be assigned to a right-click pop-up menu in the same way as described above, with no restriction imposed by the sub-menu depth.

As assigned, the custom Notepad script command becomes available in the PCB editor when right-clicking in free space. A custom command assigned to a right-click sub-menu. As an alternative to creating a reusable custom command from a script then assigning it to a menu, a script can be directly applied to a menu as a quick, one-off approach. This bypasses the creation of a custom command step by directly assigning a loaded script to a menu. Without the existence of a matching custom command, which can be applied as a fully configured command to multiple menus, this direct method is a singular solution for script menu access.

As such, the various command settings, such as its Caption, Description, Image and Shortcuts only apply to the assigned instance. To assign a script directly to a menu, load the script project, open the server’s Customizing dialog View » Toolbars » Customize , select [Scripts] in the Categories list, locate the desired script and drag it to a menu position. Click to dismiss the Edit Command dialog.

A script, rather than a command, can also be assigned directly to a menu. As with all menu placements, if the new menu item is still at its default settings caption name, shortcut etc , these can be corrected by right-clicking on the menu entry and selecting Edit from the submenu. This opens the Edit Command dialog where suitable settings can be entered. In Customizing mode, right click on a menu to access its parameters.

 
 

Run Script | Online Documentation for Altium Products.Scripting Examples Reference for Altium Designer | Altium Designer 22 User Manual | Documentation

 
 
Using Altium Documentation. This script demonstrates how to create a new Via object on a PCB document. Printer-friendly version. The script will then generate a netlist for the current project, so make sure the project is focused before the script is run.